Powfrax <sup>®</sup> HT900 Series 600-900°C<br />
High-Temperature Dust Removal Ceramic Fiber Filter for South Africa

Application: Ultra-low dust purification and acidic component removal for high-temperature flue gas from industrial furnaces at 600-900℃.
Performance: Dust removal efficiency ≥ 99% (typical particulate emission concentration < 5 mg/Nm3, minimum can be < 1 mg/Nm3).
Temperature: HT900 High-Temperature Series: 600-900°C.
Features: High porosity (>80%), high strength, low resistance (<300pa per meter per minute), ultra-long service life. Fully replaces electrostatic precipitators and fabric filters.
Warranty: 5 years, with a service life of up to 8-10 years under specific conditions.

Learn More

Under high-temperature flue gas conditions of up to 600-900°C, traditional dust removal processes face issues of insufficient high-temperature resistance, high reliability, and maintenance costs.

  • 1. Bag Filter: Traditional filter bags (such as PTFE fiber) can only withstand temperatures up to 300°C, and overheating can cause "burned bags" or "clogged bags," requiring additional cooling systems, which leads to wasted thermal energy.
  • 2. Electrostatic Precipitator: The upper operating temperature limit is approximately 370°C, and overheating can cause changes in dust properties (such as increased viscosity and resistivity jumps), reducing efficiency; prolonged high temperatures also lead to plastic deformation of components and insulation failure.
  • 3. Cyclone Separator: Although it can withstand temperatures of 800-900°C, its collection efficiency for fine particles below 10μm (such as PM2.5) is less than 50%, failing to meet stringent emission standards.​
  • 4. Filter bags have a significantly reduced lifespan when subjected to erosion from high-temperature hard particles (such as metallurgical iron oxide).
  • 5. Wet dust removal (such as venturi tubes) consumes a large amount of water, produces secondary pollution (wastewater/sludge), and cannot recover waste heat from high-temperature flue gas.
  • 6. Metal sintering mesh dust removal requires a pulse blowback system, which has a complex structure and is prone to sintering blockage at high temperatures

The Powfrax HT900 high-temperature dust removal ceramic fiber filter tube can maintain ultra-high reliability and dust removal efficiency even under working conditions of 600-900 degrees. Thanks to its ultra-high porosity, air to cloth ratio, and ultra small nanoscale pore size, it is possible to achieve 99% of industrial dust and particulate matter, including PM10, PM2.5, and PM1. The ceramic filter tube surface forms a unique adsorbent filter cake, which can simultaneously remove over 95% of acidic components in flue gas. The typical emission concentration of industrial dust and particulate matter in flue gas treatment projects using ceramic filter tubes is less than 5mg/Nm3, and can even reach<1mg/Nm3. Its normal service life exceeds 5 years, and under specific working conditions, it can even reach 8-10 years.


With the integration of ceramic technology, dust removal, denitrification, desulfurization, reduction of ammonia escape, removal of dioxins and other functions can be achieved simultaneously in the same system, greatly reducing the system's footprint and annual environmental protection costs.


he HT900 high-temperature dust removal ceramic fiber filter is developed based on the improvement of the ceramic fiber filter process.
For its raw material characteristics and process flow, please refer to Powfrax® ceramic fiber filter

Understand the production process

High-temperature dust removal characteristics
Can adapt to 600-900 degree high-temperature conditions

ultrafiltration-characteristics-of-ceramic-fibers

On the basis of ordinary ceramic fiber filter tubes, by adjusting the raw material ratio and improving the process, the HT900 series ceramic fiber filter tubes still have up to 99% dust removal and filtration characteristics under high temperature conditions of 600-900 degrees.


Strictly control the quality of ceramic fiber cotton, the raw material for ceramic filter tubes; The inner wall of the ceramic filter tube is evenly layered with fabric to ensure strength and porosity; Ceramic filter tube flange and plug are reinforced and solidified to improve strength.

Ceramic Fiber Filter Parameter


Ceramic-fiber-filter-parameters.png

Our customers

Since 2017, we have implemented over 50 glass furnace ceramic integrated flue gas purification projects for companies such as Wuliangye in Yibin, Shandong Pharmaceutical Glass, Sichuan University of Science and Technology, Anhui Shengshi, Shandong Luzhong, Shandong Jingyao Glass, and Luzhou Huasheng. Among these, the "Luzhou Liquor Industry" three-line air glass melting furnace environmental protection project is the first third-party operation project in China for daily glass furnace air pollution control adopting an "investment + operation" model. The "Sichuan University of Science and Technology" full-oxygen glass melting furnace is the first environmental protection project in China to use ceramic filter tubes + SCR denitrification technology for full-oxygen glass melting furnaces.

ZTW-Partial-Customer-List

South Africa Industrial Flue Gas Filtration

ZTW Tech supplies ceramic catalytic filter elements and ceramic fiber filter elements to South Africa industrial operators. Local project pricing is quoted in R (ZAR), and every quotation includes technical drawings and a technical data sheet in metric units.

Key industries served in South Africa

Standards and compliance for South Africa

Applications by industry

Coal-fired power stations
Eskom coal units with boiler inlet gas at 140-180°C and very high particulate loading. Ceramic elements are installed ahead of the ESP where retrofit space is tight and baghouse duty is too severe.
Lime and cement kilns
Rotary kilns with a burning zone at 1450°C and a precalciner at 1050°C. The NOx reduction duty sits after the tertiary duct, and the duty is matched to the SAAQIS emission limits applied at the stack.
Base metal smelting
Flash and reverberatory furnace off-gas at 700-1000°C with high SO2 and dusty conditions. The catalytic element chemistry suits the sulphur load and the low-silica dust typical of base metal routes.

Regulatory compliance in South Africa

Industrial emissions in South Africa are governed by the National Environmental Management: Air Quality Act 39 of 2004, with SAAQIS emission limits as the compliance reference and provincial environmental authorisation from the relevant department. Filter media and equipment are commonly specified to SANS standards, with MPRDA and NEMA permitting applied to the wider project, and continuous emission monitoring is a normal condition of licence.

Supply, lead time and logistics

Quotations are issued in ZAR with 30-day validity. Elements are shipped by sea to Durban, Cape Town or Port Elizabeth, typically 24-32 days, or by air in 7-10 days. Stocked diameters are held for 3-day dispatch, and the full installation document set accompanies every shipment.

South Africa

Technical support is provided in English with R quotation and local lead-time guidance. Request a free filter sample or discuss an OEM / ODM programme.

Search coverage for South Africa

Content for South Africa is indexed in Google South Africa, Bing South Africa.

Frequently asked questions

Will the elements satisfy the Air Quality Act and SAAQIS limits?
Yes. We supply the material data, permeability and hot-strength test reports and the performance curve needed for an environmental authorisation or licence variation, together with the data required for continuous emission monitoring interpretation.
What are the lead times to South Africa?
24-32 days by sea to Durban, Cape Town or Port Elizabeth and 7-10 days by air, with stocked diameters dispatched within 3 days. We state the manufacturing window, the port of discharge and the estimated arrival on every quotation.
Do you support South African installation and O&M contractors?
Yes. We provide installation drawings, torque specifications and commissioning checklists, and we support local O&M contractors through the performance test so the guaranteed figures are reproduced on site under South African operating conditions.
ZTW
We will reach you within 1 hour.
2026-11-27 09:02:43
Hello, welcome to ZTW. Please reach out to us at any time.
We have received your ticket and will get back to you within 24 hours.
Cancel

Select the chat tool: